Gensets
50 HZ
5 kVA
7.5 kVA – 15 kVA
20 kVA – 25 kVA
30 kVA – 40 kVA
50 kVA – 62.5 kVA
82.5 kVA – 125 kVA
160 kVA – 200 kVA
250 kVA – 320 kVA
400 kVA
700 kVA TO 3500 kVA
Shield Plan
Control Panel
Alternator
Downloadable Brochures

Genset dealers:

Ashok Leyland Generator Dealer

While power cuts get to your profits, an inefficient diesel Generator sets are designed to make
sure you an efficient power supply. Moreover, assures you years of trouble-free operation.

Generates peace of mind

Its recovery time, simply the best in its class guarantees a seamless switchover to the back-up power. Also,its effective governing system controls the voltage fluctuations, therefore succeeding complete safety of your equipment’s.

Performance unmatched

Its got one of the foremost most popular engines fitted inside – the pioneer engine. Close and low on vibration, this engine has the littlest footprint as compared to other engines of identical ratings. Creating the Diesel Generator set apt even for roof-mountings.

Silence certified

Each and each Powerol Diesel Generator set complies with the foremost demanding noise and emission norms stipulated by the Central Pollution Control Board of India(CPCB).

No Compromise technology

  • Get alternative benefits too. Like, it’s transported through the Pioneer Transport Solutions Group. It’s put in(installed) and commissioned through a Pioneer Authorized dealer.
  • Even comes with an annual maintenance contract.
  • Most fuel-efficient in its category.
  • Offers zero-leak engines.
  • Manual and AMF control panel choices are also available.

Preferred by all

Diesel Generator set will be used in the telecommunication, Defence and Railway sectors. It also can be put in(installed) at places like fuel pumps, hospitals, supermarkets, banks and construction sites.

Unique Features of Mahindra’s Gas Powered Gensets

Water cooled Turbocharger

  • This technology, used for the first time in gas gensets helps in achieving 0% power deration
  • Makes the genset more compact

Low Noise emission

  • Optimised design helps in reducing the noise by 4 dbA without any  increase in genset size and extra silencer

Low exhaust emissions

  • Zero emission of harmful particulate and smoke
  • 35% lesser emissions of pollutants like NOx, HC and CO

Maximum fuel Effectiveness

  • Electronically controlled air fuel ratio
  • Closed loop lambda feedback system

Lowest Operating Cost

  • Operating price is 45% less than that of conventional Gensets
Frame Size G1R200 MD G1R250SB
kVA 82.5 100
KW 66 80
Frame Size G1R250SD G1R250MA
kVA 125 140
KW 100 112
Frame Size G1R250MB G1R250LB
kVA 160 180
KW 128 144
Frame Size G1R250LD G1R315SE
kVA 200 250
KW 160 200
Frame Size G1R355SB G1R355SE
kVA 400 500
KW 320 400
Frame Size G1R315SB
kVA 320
KW 256
Parameters DG models
50 Hz Prime Rating (KVA) 5
Rated (KWe) 4
Engine Model 15LD440-GSI2
No of Cylinders 1
Rated Speed RPM 3000
Rated Current(AMP) Capacity @ 0.8PF  1 Phase
3 Phase NA
Cooling System (Air Cooled/Water Cooled) Air
Door Type SD
Side lifting DG set dimensions with top hood, if any (mm) Length 1080
Width 700
Height 765
Intergrated Fuel Tank Capacity (lits) 20
Approximate Dry Weight  of DG set (Kg) 225
Centre lifting DG set dimensions with top hood, if any (mm) Length 1050
Width 700
Height 745
Parameters LEAF DG Model
50 Hz Prime Rating (KVA) 7.5kVA 10kVA 15kVA
Rated (KWe) 6 8 12
Engine Model 2185GM-C2 2185GM-C2 2205GM-C2
No of Cylinders 2 2 2
Rated Speed RPM 1500 1500 1500
Rated Current(AMP) Capacity @ 0.8PF  1 Phase 32.6 43.5 65.25
3 Phase 10.4 13.9 20.9
Cooling System (Air Cooled/Water Cooled) Water Cooled Water Cooled Water Cooled
DG Lifting Type SL SL SL
DG set dimension with top hood if any (mm) Length 2215 2215 2215
Width 1050 1050 1050
Height 1336 1336 1336
Intergrated Fuel Tank Capacity (lits) 85 85 85
Approximate Weight of DG set (Kg) 800 800 800
ParametersDG models
50 Hz PrimeRating (KVA)2022.52525
Rated (KWe)16182020
Engine Model3285GM-C23335TCGM-C23385TCIGM-C23385TCIGM-C2
No of Cylinders3333
Rated Speed RPM1500150015001500
Rated Current(AMP) Capacity @ 0.8PF 1 Phase8797.8108.7108.7
3 Phase27.831.334.834.8
Cooling System (Air Cooled/Water Cooled)WaterWaterWaterWater
Door TypeSDSDSDDD
Side lifting DG set dimensions with top hood, if any (mm)Length2120215021202500
Width90010309001030
Height1410136514101376
Intergrated Fuel Tank Capacity (lits)909090130
Approximate Weight of DG set (Kg)800800820940
Centre lifting DG set dimensions with top hood, if any (mm)Length2150215025002500
Width1030103010301030
Height1300130013901390
 
Parameters
50 Hz Prime Rating (KVA) 30 40
Rated (KWe) 24 32
Engine Model 3445TCIGM-C2 4575TCIGM-C2
No of Cylinders 3 4
Rated Speed RPM 1500 1500
Rated Current(AMP) Capacity @ 0.8PF  1 Phase 130.4 173.9
3 Phase 41.7 55.6
Cooling System (Air Cooled/Water Cooled) Water Water
Door Type DD DD
Side lifting DG set dimensions with top hood, if any (mm) Length 2500 2500
Width 1030 1030
Height 1376 1376
Intergrated Fuel Tank Capacity (lits) 130 130
Approximate Weight of DG set (Kg) 950 1000
Centre lifting DG set dimensions with top hood, if any (mm) Length 2500 2500
Width 1030 1030
Height 1390 1390
Parameters DG models
50 Hz Prime Rating (KVA) 50 62.5
Rated (KWe) 40 50
Engine Model 4725GM-C2 4905GM-C2
No of Cylinders 4 4
Rated Speed RPM 1500 1500
Rated Current(AMP) Capacity @ 0.8PF  1 Phase NA
3 Phase 69.6 87
Cooling System (Air Cooled/Water Cooled) Water Water
Door Type DD DD
Side lifting DG set dimensions with top hood, if any (mm) Length 2770 2770
Width 1150 1150
Height 1800 1800
Intergrated Fuel Tank Capacity (lits) 150 150
Approximate Dry Weight of DG set (Kg) 1250 1250
Centre lifting DG set dimensions with top hood, if any (mm) Length 2800 2800
Width 1150 1150
Height 1540 1540
Parameters DG Model
50 Hz Prime Rating (KVA) 75 82.5 100 125
Rated (KWe) 60 60 66 80 100
Engine Model 41035GM-C2 41035GM-C2 Standby 82.5 KVA Mech CPCB II 100 KVA Mech CPCB II 125 KVA Mech CPCB II
No of Cylinders 4 4 4 4 6
Rated Speed RPM 1500
Rated Engine Power at 100% load KW (HP) 68.9 (93.6) 74.5 (101.2) 93 (126.4) 114.8 (156)
Rated Current(AMP) Capacity @ 0.8PF 1 Phase NA
3 Phase 104.3 115 139 173.9
Cooling System Water Cooled
Door Type DD DD DD DD
Side lifting DG set dimensions with top hood, if any (mm) Length 3000 3200 3200
Width 1150 1300 1300
Height 2135 2290 2290
Intergrated Fuel Tank Capacity (lits) 230 200 200 219
Approximate Weight of DG set (Kg) 1350 1700 1720 1866
Centre lifting DG set dimensions with top hood, if any (mm) Length 2800 3200 3200 3750
Width 1150 1300 1300 1030
Height 1640 1700 1700 1533
Parameters DG Model
50 Hz Prime Rating (KVA) 160 180 200
Rated (KWe) 128 144 160
Engine Model 160 KVA Mech CPCB II 180 KVA Elec CPCB II 200 KVA Elec CPCB II
No of Cylinders 6 6 6
Rated Speed (RPM) 1500
Rated Engine Power KW (HP) 146.5 163 180
199 221.5 244.6
Rated Current(AMP) Capacity @ 0.8PF 1 Phase NA
3 Phase 222.6 250.4 278.2
Cooling System Water Cooled
Door Type DD DD DD
Side lifting DG set dimensions with top hood, if any (mm) Length 3790 4500 4500
Width 1300 1500 1500
Height 1877 1878 1878
Intergrated Fuel Tank Capacity (lits) 250 390 390
Approximate Weight of DG set (Kg) 2350 2750 2800
Centre lifting DG set dimensions with top hood, if any (mm) Length 3750
Width 1300
Height 1700
Genset Specification
Genset Prime Rating (kVA) * 250 320
Genset Prime Rating (KW) 200 256
3 / 415
Power Factor 0.8 (lagging)
Current (A) 348 445
Frequency (Hz)& RPM 50/1500
Governing class G2 as per ISO 8528 Part V
Starting system 24 V DC Elec
Fuel tank capacity 575 575
Canopy dimensions w/o silencer (mm) (L x W x H) approx. 4600 x 1700 x 2025 4800 x 1700 x 2025
Genset Weight (kg) approx. 3700 3950
Engine Specification
Make / Series Mahindra mPower
Engine Model mPower63105G mPower63905G
Rated Power at 100% Load @ 1500 RPM (HP) 310 390
Aspiration Turbocharged Aftercooled
No. of cylinders 6
Bore x Stroke (mm) 116.6 x 146.1
Displacement (Lit) 9.3
Alternator
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%
Genset Prime Rating (kVA) * 500
Genset Prime Rating (KW) 400
Phase / Voltage (V) 3/415
Power Factor 0.8 (lagging)
Current (A) 695
Frequency (Hz)& RPM 50/1500
Governing class G2 as per ISO 8528 Part V
Starting system 24 V DC Elec
Fuel tank capacity 900
Canopy dimensions w/o silencer (mm) (L x W x H) approx. 5950x200x2350
Genset Weight (kg) approx. 6500
Engine Specification
Make / Series Perkins
Engine Model 2506D-E15TAG2
Rated Power at 100% Load @ 1500 RPM (HP) 605
Aspiration Turbo Charged After Cooled
No. of cylinders 6
Bore x Stroke (mm) 137*171
Displacement (Lit) 15.2
Fuel consumption @ 75% load (kg/hr) ** 80
Fuel consumption @ 100% load (kg/hr)** 103
Total lubrication system capacity (lit) 62
Lube oil consumption @ 100% load $ 0.10%
Lube oil change period (hrs.) 500
Radiator coolant capacity (liter) 48
Lube oil change period (hrs.) 500
Alternator
Enclosure Type IP 23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

Regarding 700kVA & above requirements, you can directly contact our Sales Head @ :- +91 9940577409

generator dealers in chennai

Powerol Diesel Generators are renowned for delivering uninterrupted power. Now, with the SUPER SHIELD PLAN, Powerol takes its reliability even further. Super Shield is a 5-year all-inclusive coverage plan. Which means, zero repair charges, zero service charges and zero spare replacement costs, for five whole years.
This plan defies the standard industry norms of 2 years warranty on diesel generators.

This offer is applicable for ranges from 82.5KVA to 200KVA DG sets.

 

Control Panel Specifications
Control PanelAMFMCP
Upto 125kVA Mahindra EnginesBerniniProcom
125 to 160kVA with ControllerDeepsea 6020 / 4520Deepsea 6020 / 4520
180 to 200kVA with ControllerDeepsea 7320 with GPRS / 4520Deapsea 7320 with GPRS / 4520
250 to 500kVA with ControllerDeepsea 6020 / 4520Deepsea 6020 / 4520
Failure ModesOver voltage/ Under voltage
Over Frequency /Under Frequency
LLOP
High water Temperature
Low Fuel Level
Over Load
Frame Size G1R200 MD G1R250SB
kVA 82.5 100
KW 66 80
Frame Size G1R250SD G1R250MA
kVA 125 140
KW 100 112
Frame Size G1R250MB G1R250LB
kVA 160 180
KW 128 144
Frame Size G1R250LD G1R315SE
kVA 200 250
KW 160 200
Frame Size G1R355SB G1R355SE
kVA 400 500
KW 320 400
Frame Size G1R315SB
kVA 320
KW 256